are industrial-grade central chilled water systems designed for marine, commercial, offshore, and drydock applications where raw seawater cooling is impractical, undesirable, or unavailable.
Eliminates raw water pumps, strainers, sea cocks, and marine growth fouling by discharging heat directly into ambient air.
Allows full vessel HVAC operation while hauled out of water for maintenance or operating in shallow/silty waterways.
Built on a heavy-duty marine-grade stainless steel chassis with weather-coated condenser coils for harsh salt-air environments.

| Model / Code | Cooling Capacity | Series / Form Factor | Electrical Configuration | Recommended Application |
|---|---|---|---|---|
| FM24CWAC | 24,000 BTU/hr (2.0 Tons) |
CWAC Standard Horizontal | 208-230V / 1-Phase / 60Hz | Small workboats, patrol vessels, and compact wheelhouse chilled loops. |
| FM60CWAC | 60,000 BTU/hr (5.0 Tons) |
CWAC Standard Horizontal | 208-230V / 1-Phase or 3-Phase | Commercial tugs, houseboats, and small multi-cabin vessels. |
| FM60SSAC | 60,000 BTU/hr (5.0 Tons) |
SSAC Heavy-Duty Scroll | 208-230V / 1-Phase or 3-Phase | Offshore supply craft and heavy industrial deck-mounted installations. |
| FM120CWAC-V | 120,000 BTU/hr (10.0 Tons) |
CWAC Vertical Cabinet | 208-230V / 460V / 3-Phase | Vertical mechanical closets and tight engine room enclosures. |
| FM120SSAC-V | 120,000 BTU/hr (10.0 Tons) |
SSAC Vertical Cabinet | 208-230V / 460V / 3-Phase | Commercial vessel vertical utility rooms and shipyard drydock operations. |
| FM120CWAC-H | 120,000 BTU/hr (10.0 Tons) |
CWAC Horizontal Cabinet | 208-230V / 460V / 3-Phase | Open deck mounts, upper flybridge equipment spaces, and barges. |
| FM120SSAC-H | 120,000 BTU/hr (10.0 Tons) |
SSAC Horizontal Cabinet | 208-230V / 460V / 3-Phase | Heavy-duty horizontal deck units on passenger ferries and workboats. |
| FM180CWAC | 180,000 BTU/hr (15.0 Tons) |
CWAC Multi-Stage Array | 208-230V / 460V / 3-Phase | Large passenger vessels, excursion boats, and central plant HVAC. |
| FM180SSAC | 180,000 BTU/hr (15.0 Tons) |
SSAC Multi-Stage Array | 208-230V / 460V / 3-Phase | Offshore platforms, military work craft, and large commercial ships. |
| FM240CWAC | 240,000 BTU/hr (20.0 Tons) |
CWAC Quad-Stage Circuit | 208-230V / 460V / 3-Phase | High-tonnage commercial vessels, cruise barges, and naval installations. |
| FM240SSAC | 240,000 BTU/hr (20.0 Tons) |
SSAC Quad-Stage Circuit | 208-230V / 460V / 3-Phase | Industrial marine central plants requiring heavy-duty scroll staging. |
| FM360SSAC | 360,000 BTU/hr (30.0 Tons) |
SSAC Commercial Quad Array | 460V / 3-Phase / 50/60Hz | Maximum-capacity air-cooled central HVAC plants for major commercial vessels. |
Design
Central air-cooled marine chilled water plant built on a rigid 316 stainless steel chassis, incorporating high-static air condenser fans, isolated scroll compressors, and an NEMA electro-mechanical control enclosure.
Application
-
Commercial Workboats & Barges: Central vessel cooling without seawater intake clogging in muddy or shallow waters.
-
Drydock Maintenance & Shipyards: Continuous climate control for crew quarters while ships are out of the water.
-
Houseboats & Dockside Installations: Maintenance-free cooling for vessels moored in marinas with high silt, weeds, or marine growth.
Type Key
| Code Segment | Description |
| Model Example | FM120CWAC-V / FM120SSAC-H |
| FM | Flagship Marine Brand Identifier |
| 24 – 360 | Nominal Capacity in Thousands of BTU/hr (24 = 24,000 BTU/hr | 360 = 360,000 BTU/hr) |
| CWAC | Chilled Water Air-Cooled Configuration |
| SSAC | Stainless Steel Cabinet / Scroll Staged Air-Cooled Unit |
| V | Cabinet Orientation (V = Vertical Configuration for Closet/Locker Mounts) |
| H | Cabinet Orientation (H = Horizontal Configuration for Deck/Mechanical Room Mounts) |
Materials
-
Chassis & Frame: Heavy-gauge 316 marine-grade stainless steel with deep structural support.
-
Air-Cooled Condenser Coil: High-efficiency copper tubes with heavy-duty, marine-coated aluminum fins.
-
Evaporator Exchanger: Insulated stainless steel brazed-plate heat exchanger for the closed glycol/water loop.
Construction
-
Condenser Fan Assembly: Weatherproof, high-CFM motor-driven axial fans engineered for efficient outdoor heat rejection.
-
No-PCB Electro-Mechanical Control: Heavy-duty relays, contactors, and terminal blocks without delicate electronic circuit boards.
-
Vibration Isolation: Multi-point rubber vibration dampers under scroll compressors to mitigate hull noise transmission.
Scope of Delivery
-
Air-Cooled Chiller Unit: Factory-assembled and pressure-tested unit with compressors, air condenser coil, fans, and brazed-plate evaporator.
-
Control Display Package: Wall-mounted digital thermostat display, water loop temperature probes, and wiring harness.
-
Documentation: Detailed installation manual, electrical schematics, and Flagship Marine factory warranty.
Can't find the part you need?
Tell us what you're looking for and we'll get back to you with a price.